90 Minute Fire Rated Cabinets are designed to protect the chemicals inside and allow emergency services plenty of time to attend and help staff and visitors to vacate the premises. The fire resistant cabinets comply, and have been tested to EN 14470-1

90 MINUTE FIRE RATED CABINET 600

Single Door 90 Minute Cabinets

90 MINUTE 1 DOOR FIRE RATED CABINET

Model 794+E

  • Shipping Dimensions; 2150 high x 1200 wide x 800 mm deep
  • Weight 287 kg
  • Ventilation; Both inlet and outlet on the back wall of the cabinet
  • Single Compartment
  • Supplied with 3 shelves (Load capacity 30 kg)
  • Self closing door
  • Manufactured in France
  • Designed for the storage of Flammable liquids with built in sump

 

2- DOOR TALL SAFETY CABINET TYPE 90

90 MINUTE 2 DOOR FIRE RATED CABINET


Model 795+E

  • External Dimensions; 1950 high x 1137 wide x 620 mm deep
  • Weight 453 kg
  • Ventilation; Both inlet and outlet on the back wall of the cabinet
  • Single Compartment
  • Supplied with 3 shelves (Load capacity 30 kg)
  • Self closing doors
  • Manufactured in France
  • Designed for the storage of Flammable liquids with built in sump

EN 14470-1 and 14470-2 EUROPEAN Standards;

The new European norm came into effect in October 2004 and concerns the storage of flammable products in laboratories. It also only concerns the safety cabinets that have an internal volume that is equivalent or less than 1 m3.

14470-2

The new European norm 14470-2 came into effect on April 2006 and concerns the storage of gas cylinders in laboratories. It also only concerns the safety cabinets with a total internal volume less than 220 litres.

The Main Requirements of the standards are shown below.

1. FIRE PROTECTION


In case of fire, the safety cabinet shall protect for at least 15 minutes that the contents of the cabinet do not contribute to any additional risks or spread of fire. A fire safety storage cabinet shall be classified as one of the types listed below :

2. FIRE TEST


All cabinets described on this page have succeeded a fire test according to EN 14770-1 (2004) or EN 14470-2 (2006) norms These tests were conducted by an outside laboratory accredited by COFRAC.

3. SPILL CONTAINMENT SUMP (ONLY FOR EN 14470-1)


A spill containment sump shall be installed underneath the lowest storage level. The sump shall have a minimum capacity of 10% of the volume of all containers stored in the cabinet, or at least, 110% of the volume of the largest single container, whichever is the greater.

4. CONSTRUCTION


The doors of the cabinet must be fully self-closing from any position. The side and back walls must be of the same thickness and comparable construction. Requirements are given in respect of the construction of the cabinet and its capacity to resist fire conditions from the outside (Fire test given in ISO 834-1 and EN 1363-1).

5. MARKING AND LABELLING


Cabinets must be fitted with its standardised pictograms in accordance with ISO 3864 :

6. VENTILATION


Safety Cabinets must have air inlet and outlet as well as a thermo-fuse which seals off the ventilation system in case of fire. These could be used to connect a forced ventilation system. The air change must be at least 10 times the volume of the safety cabinet (doors closed).

Please find the full range of sizes available in the 90 minute flammable liquid storage safes here.

Contact Us
Please contact us if you have any questions such as price or lead times. Merlin Industrial Products Ltd Unit A43 Kingsley Close, Lee Mill Industrial Estate Ivybridge Devon PL21 9LL United Kingdom Call: 01752 690622 Fax: 01752 313333
Please enter your name!
Please enter your email!
Please let us know which item you need information on as we have 1200 pages.
Write your message!